{"id":1020,"date":"2026-11-05T12:30:37","date_gmt":"2026-11-05T07:00:37","guid":{"rendered":"https:\/\/www.spalloys.com\/blog\/?p=1020"},"modified":"2026-11-26T12:33:52","modified_gmt":"2026-11-26T07:03:52","slug":"copper-bar-grades-for-electrical-and-plumbing-components","status":"publish","type":"post","link":"https:\/\/www.spalloys.com\/blog\/copper-bar-grades-for-electrical-and-plumbing-components\/","title":{"rendered":"Which Copper Bar Grades Are Suitable for Electrical and Plumbing Components?"},"content":{"rendered":"<p><span style=\"font-weight: 400;\">C10100, C10200 and C11000 cover most electrical component work, while C12200 handles water-service parts. Copper bars carry current in switchgear and feed machined fittings in plumbing lines. Engineers choose copper for its electrical conductivity, heat transfer, corrosion resistance and ease of fabrication. Each grade balances those four differently: higher purity lifts conductivity, phosphorus deoxidation improves brazing, tellurium cuts machining time. Choosing correctly between <\/span><b>copper bar grades for plumbing applications<\/b><span style=\"font-weight: 400;\"> and electrical grades determines whether the finished component performs reliably in service.<\/span><\/p>\n<h2><b>Why Copper Bars Are Used in Electrical and Plumbing Components<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Pure copper conducts electricity at roughly 100% IACS, so conductor cross-sections stay compact and joint losses stay low. Thermal conductivity near 390 W\/m\u00b7K moves heat away from busbar connections and heat exchanger parts. A stable surface oxide film resists atmospheric attack and most potable water chemistries. Fabricators bend, machine, braze and solder copper without specialised tooling. Components that sit in damp or fully submerged service hold their integrity for decades, which accounts for copper&#8217;s record across both trades.<\/span><\/p>\n<h2><b>Common Copper Bar Grades for Electrical and Plumbing Applications<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Five grades account for the bulk of component demand in these two sectors. Suppliers stock them as <\/span><a href=\"https:\/\/www.spalloys.com\/copper-bars-supplier-stockist.html\"><b>copper bars<\/b><\/a><span style=\"font-weight: 400;\">, flats and rods under ASTM B187 and related specifications.<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>C10100 \/ OFE Copper:<\/b><span style=\"font-weight: 400;\"> oxygen content below 0.0005% and conductivity rated at 101% IACS. The vacuum-melted route removes residual gases almost completely. High-power conductors, waveguides and vacuum-tube components rely on that purity, since even trace oxide inclusions disturb electrical and thermal behaviour.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>C10200 \/ OF Copper:<\/b><span style=\"font-weight: 400;\"> oxygen-free copper delivering 100% IACS with strong resistance to hydrogen embrittlement. Parts joined by hydrogen-bearing brazing or welding cycles hold up where tough pitch copper would crack. Electrical conductors and sealed assemblies both use it.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>C11000 \/ Electrolytic Tough Pitch (ETP) Copper:<\/b><span style=\"font-weight: 400;\"> the most widely produced commercially pure grade. A small residual oxygen content refines the grain and improves formability, and conductivity remains at 100% IACS. Fabricators roll, punch and bend it into <\/span><b>copper busbar sections<\/b><span style=\"font-weight: 400;\">, terminals and earthing bars.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>C12200 \/ DHP Copper:<\/b><span style=\"font-weight: 400;\"> phosphorus-deoxidised copper carrying 0.015 to 0.040% phosphorus. Conductivity falls to about 85% IACS, but weldability and brazing performance improve sharply. Tube, fittings and <\/span><b>DHP copper tube stock<\/b><span style=\"font-weight: 400;\"> for water service use this grade almost exclusively.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>C14500 \/ Tellurium Copper:<\/b><span style=\"font-weight: 400;\"> 0.40 to 0.70% tellurium raises the machinability rating to around 80 to 90% of free-cutting brass, with conductivity still near 90% IACS. Screw-machined contacts and turned connector bodies suit it well.<\/span><\/li>\n<\/ul>\n<h2><b>Which Copper Grades Are Best for Electrical Components?<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Conductivity governs grade choice here because every percentage point lost raises resistive heating at the joint. C11000 handles the majority of busbars, connectors, terminals and switchgear parts, and it costs less than the oxygen-free grades. C10100 and C10200 step in where brazed joints, vacuum sealing or very high current densities make residual oxygen a liability. Heavy machining work shifts the balance: <\/span><b>tellurium copper rods<\/b><span style=\"font-weight: 400;\"> trade a little conductivity for far shorter cycle times. Required conductivity, fabrication route and operating conditions together decide the specification.<\/span><\/p>\n<h2><b>Which Copper Grades Are Suitable for Plumbing Applications?<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">C12200 dominates water-service component production. Deoxidation with phosphorus leaves no oxygen to react during brazing, so joints stay sound through repeated thermal cycles. The grade resists corrosion in most potable and chilled water systems, and it forms cleanly into fittings, tubes, valve bodies and connection pieces. Water chemistry still matters: soft, acidic or high-chloride supplies accelerate attack, and elevated temperature or pressure narrows the safe envelope. Check applicable plumbing codes and water quality data before you confirm the material.<\/span><\/p>\n<h2><b>Factors to Consider When Selecting a Copper Bar Grade<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">The following technical and commercial points shape the final grade decision.<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Required electrical conductivity in % IACS<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Corrosion exposure and surrounding environment<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Compatibility with the water or process fluid carried<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Mechanical strength and hardness are needed in service<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Machining volume and tolerance requirements<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Welding, brazing or soldering method planned<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Maximum continuous operating temperature<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Component dimensions and available bar sizes<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Applicable ASTM and UNS designations<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Supplier quality systems and mill test certification<\/span><\/li>\n<\/ul>\n<h2><b>Copper Bar Grades: Electrical vs Plumbing Applications<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Selecting the right copper bar grade ensures reliable performance. Here is how common grades compare for electrical and plumbing applications:<\/span><\/p>\n<table>\n<tbody>\n<tr>\n<td><b>Copper Grade<\/b><\/td>\n<td><b>Key Property<\/b><\/td>\n<td><b>Typical Application<\/b><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">C10100<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Very high conductivity<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Electrical components<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">C10200<\/span><\/td>\n<td><span style=\"font-weight: 400;\">High conductivity<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Electrical components<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">C11000<\/span><\/td>\n<td><span style=\"font-weight: 400;\">High conductivity and formability<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Electrical components<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">C12200<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Good weldability and corrosion resistance<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Plumbing components<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">C14500<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Improved machinability<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Machined electrical components<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"font-weight: 400;\">Treat the table as a starting point. Match the grade to the component&#8217;s actual operating load and fabrication sequence rather than to its general category.<\/span><\/p>\n<h2><b>Conclusion<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Copper grades differ measurably in conductivity, machinability, weldability and corrosion behaviour, and those differences decide fitness for purpose. C10100, C10200 and C11000 answer most electrical duties, while C12200 remains the reference choice among <\/span><b>copper bar grades for plumbing applications<\/b><span style=\"font-weight: 400;\"> and water-service parts. Confirm operating conditions, applicable standards and fabrication requirements against mill certification before you release a purchase order.<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>C10100, C10200 and C11000 cover most electrical component work, while C12200 handles water-service parts. Copper bars carry current in switchgear and feed machined fittings in plumbing lines. Engineers choose copper for its electrical conductivity, heat transfer, corrosion resistance and ease of fabrication. Each grade balances those four differently: higher purity lifts conductivity, phosphorus deoxidation improves [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":1022,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[133],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v22.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Copper Bar Grades for Electrical and Plumbing Components<\/title>\n<meta name=\"description\" content=\"Compare C10100, C10200, C11000, C12200 and C14500 copper bar grades for electrical &amp; plumbing components, conductivity, machinability and applications.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.spalloys.com\/blog\/copper-bar-grades-for-electrical-and-plumbing-components\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Copper Bar Grades for Electrical and Plumbing Components\" \/>\n<meta property=\"og:description\" content=\"Compare C10100, C10200, C11000, C12200 and C14500 copper bar grades for electrical &amp; plumbing components, conductivity, machinability and applications.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.spalloys.com\/blog\/copper-bar-grades-for-electrical-and-plumbing-components\/\" \/>\n<meta property=\"og:site_name\" content=\"Sagar Prakash Alloys\" \/>\n<meta property=\"article:published_time\" content=\"2026-11-05T07:00:37+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-26T07:03:52+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.spalloys.com\/blog\/wp-content\/uploads\/2026\/11\/Copper-Bars-for-Electrical-and-Plumbing.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1896\" \/>\n\t<meta property=\"og:image:height\" content=\"830\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Sagar Prakash Alloys\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Sagar Prakash Alloys\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.spalloys.com\/blog\/copper-bar-grades-for-electrical-and-plumbing-components\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.spalloys.com\/blog\/copper-bar-grades-for-electrical-and-plumbing-components\/\"},\"author\":{\"name\":\"Sagar Prakash Alloys\",\"@id\":\"https:\/\/www.spalloys.com\/blog\/#\/schema\/person\/2b8640ab1971d0627cd33c9a103509c3\"},\"headline\":\"Which Copper Bar Grades Are Suitable for Electrical and Plumbing Components?\",\"datePublished\":\"2026-11-05T07:00:37+00:00\",\"dateModified\":\"2026-11-26T07:03:52+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.spalloys.com\/blog\/copper-bar-grades-for-electrical-and-plumbing-components\/\"},\"wordCount\":808,\"publisher\":{\"@id\":\"https:\/\/www.spalloys.com\/blog\/#organization\"},\"articleSection\":[\"Bar Blog\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.spalloys.com\/blog\/copper-bar-grades-for-electrical-and-plumbing-components\/\",\"url\":\"https:\/\/www.spalloys.com\/blog\/copper-bar-grades-for-electrical-and-plumbing-components\/\",\"name\":\"Copper Bar Grades for Electrical and Plumbing Components\",\"isPartOf\":{\"@id\":\"https:\/\/www.spalloys.com\/blog\/#website\"},\"datePublished\":\"2026-11-05T07:00:37+00:00\",\"dateModified\":\"2026-11-26T07:03:52+00:00\",\"description\":\"Compare C10100, C10200, C11000, C12200 and C14500 copper bar grades for electrical & plumbing components, conductivity, machinability and applications.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.spalloys.com\/blog\/copper-bar-grades-for-electrical-and-plumbing-components\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.spalloys.com\/blog\/copper-bar-grades-for-electrical-and-plumbing-components\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.spalloys.com\/blog\/copper-bar-grades-for-electrical-and-plumbing-components\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.spalloys.com\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Which Copper Bar Grades Are Suitable for Electrical and Plumbing Components?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.spalloys.com\/blog\/#website\",\"url\":\"https:\/\/www.spalloys.com\/blog\/\",\"name\":\"Sagar Prakash Alloys\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/www.spalloys.com\/blog\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.spalloys.com\/blog\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.spalloys.com\/blog\/#organization\",\"name\":\"Sagar Prakash Alloys\",\"url\":\"https:\/\/www.spalloys.com\/blog\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.spalloys.com\/blog\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.spalloys.com\/blog\/wp-content\/uploads\/2024\/02\/logo.png\",\"contentUrl\":\"https:\/\/www.spalloys.com\/blog\/wp-content\/uploads\/2024\/02\/logo.png\",\"width\":766,\"height\":155,\"caption\":\"Sagar Prakash Alloys\"},\"image\":{\"@id\":\"https:\/\/www.spalloys.com\/blog\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.spalloys.com\/blog\/#\/schema\/person\/2b8640ab1971d0627cd33c9a103509c3\",\"name\":\"Sagar Prakash Alloys\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Copper Bar Grades for Electrical and Plumbing Components","description":"Compare C10100, C10200, C11000, C12200 and C14500 copper bar grades for electrical & plumbing components, conductivity, machinability and applications.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.spalloys.com\/blog\/copper-bar-grades-for-electrical-and-plumbing-components\/","og_locale":"en_US","og_type":"article","og_title":"Copper Bar Grades for Electrical and Plumbing Components","og_description":"Compare C10100, C10200, C11000, C12200 and C14500 copper bar grades for electrical & plumbing components, conductivity, machinability and applications.","og_url":"https:\/\/www.spalloys.com\/blog\/copper-bar-grades-for-electrical-and-plumbing-components\/","og_site_name":"Sagar Prakash Alloys","article_published_time":"2026-11-05T07:00:37+00:00","article_modified_time":"2026-11-26T07:03:52+00:00","og_image":[{"width":1896,"height":830,"url":"https:\/\/www.spalloys.com\/blog\/wp-content\/uploads\/2026\/11\/Copper-Bars-for-Electrical-and-Plumbing.jpg","type":"image\/jpeg"}],"author":"Sagar Prakash Alloys","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Sagar Prakash Alloys","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.spalloys.com\/blog\/copper-bar-grades-for-electrical-and-plumbing-components\/#article","isPartOf":{"@id":"https:\/\/www.spalloys.com\/blog\/copper-bar-grades-for-electrical-and-plumbing-components\/"},"author":{"name":"Sagar Prakash Alloys","@id":"https:\/\/www.spalloys.com\/blog\/#\/schema\/person\/2b8640ab1971d0627cd33c9a103509c3"},"headline":"Which Copper Bar Grades Are Suitable for Electrical and Plumbing Components?","datePublished":"2026-11-05T07:00:37+00:00","dateModified":"2026-11-26T07:03:52+00:00","mainEntityOfPage":{"@id":"https:\/\/www.spalloys.com\/blog\/copper-bar-grades-for-electrical-and-plumbing-components\/"},"wordCount":808,"publisher":{"@id":"https:\/\/www.spalloys.com\/blog\/#organization"},"articleSection":["Bar Blog"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.spalloys.com\/blog\/copper-bar-grades-for-electrical-and-plumbing-components\/","url":"https:\/\/www.spalloys.com\/blog\/copper-bar-grades-for-electrical-and-plumbing-components\/","name":"Copper Bar Grades for Electrical and Plumbing Components","isPartOf":{"@id":"https:\/\/www.spalloys.com\/blog\/#website"},"datePublished":"2026-11-05T07:00:37+00:00","dateModified":"2026-11-26T07:03:52+00:00","description":"Compare C10100, C10200, C11000, C12200 and C14500 copper bar grades for electrical & plumbing components, conductivity, machinability and applications.","breadcrumb":{"@id":"https:\/\/www.spalloys.com\/blog\/copper-bar-grades-for-electrical-and-plumbing-components\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.spalloys.com\/blog\/copper-bar-grades-for-electrical-and-plumbing-components\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.spalloys.com\/blog\/copper-bar-grades-for-electrical-and-plumbing-components\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.spalloys.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Which Copper Bar Grades Are Suitable for Electrical and Plumbing Components?"}]},{"@type":"WebSite","@id":"https:\/\/www.spalloys.com\/blog\/#website","url":"https:\/\/www.spalloys.com\/blog\/","name":"Sagar Prakash Alloys","description":"","publisher":{"@id":"https:\/\/www.spalloys.com\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.spalloys.com\/blog\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.spalloys.com\/blog\/#organization","name":"Sagar Prakash Alloys","url":"https:\/\/www.spalloys.com\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.spalloys.com\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.spalloys.com\/blog\/wp-content\/uploads\/2024\/02\/logo.png","contentUrl":"https:\/\/www.spalloys.com\/blog\/wp-content\/uploads\/2024\/02\/logo.png","width":766,"height":155,"caption":"Sagar Prakash Alloys"},"image":{"@id":"https:\/\/www.spalloys.com\/blog\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.spalloys.com\/blog\/#\/schema\/person\/2b8640ab1971d0627cd33c9a103509c3","name":"Sagar Prakash Alloys"}]}},"_links":{"self":[{"href":"https:\/\/www.spalloys.com\/blog\/wp-json\/wp\/v2\/posts\/1020"}],"collection":[{"href":"https:\/\/www.spalloys.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.spalloys.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.spalloys.com\/blog\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.spalloys.com\/blog\/wp-json\/wp\/v2\/comments?post=1020"}],"version-history":[{"count":1,"href":"https:\/\/www.spalloys.com\/blog\/wp-json\/wp\/v2\/posts\/1020\/revisions"}],"predecessor-version":[{"id":1021,"href":"https:\/\/www.spalloys.com\/blog\/wp-json\/wp\/v2\/posts\/1020\/revisions\/1021"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.spalloys.com\/blog\/wp-json\/wp\/v2\/media\/1022"}],"wp:attachment":[{"href":"https:\/\/www.spalloys.com\/blog\/wp-json\/wp\/v2\/media?parent=1020"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.spalloys.com\/blog\/wp-json\/wp\/v2\/categories?post=1020"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.spalloys.com\/blog\/wp-json\/wp\/v2\/tags?post=1020"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}